High-power Lithium Primary Battery ER34615 MP (D) 3,6V 13,5Ah
|
|
PurposeWith the goal of import substitution, as well as to ensure the technological independence of enterprises, JSC "Lithium-Element" is developing a new high‑power cylindrical current source based on the lithium/thionyl chloride electrochemical system: ER34615MP. The product will be manufactured with acceptance by the Quality Control Department and may be in demand as a replacement for currently scarce analogs, such as the LSH20 manufactured by "Saft" France. |
Purpose
With the goal of import substitution, as well as to ensure the technological independence of enterprises, JSC "Lithium-Element" is developing a new high‑power cylindrical current source based on the lithium/thionyl chloride electrochemical system: ER34615MP. The product will be manufactured with acceptance by the Quality Control Department and may be in demand as a replacement for currently scarce analogs, such as the LSH20 manufactured by "Saft" France.
Key Features:
| Parameter Name | Value |
|---|---|
| Form factor | D (R20) спиральный |
| Voltage (V) | 3.60 |
| Open circuit voltage (V) | 3.67 |
| Final discharge voltage, not less than (V) | 2.00 |
| Rated capacity (A·h) | 13.00 |
| Maximum amperage (A) | 1.80 |
| Maximum impulse discharge current at l.p.d(A) | 4.00 |
| Temperature range (°С) | -40…+75 |
| Maximum temperature range (°С) | -60…+85 |
| Weight (kg) | 0.10 |
| Physical dimensions (mm) | Ø 34,2 х 61,5 max |
| Storage life (years) | 6 |
| Warranty period (years) | 3 |
The provided characteristics make it possible to predict the operating time of the current source under various operating conditions.
The current sources are sealed, do not emit gases and electrolyte, work in any spatial position, allow the possibility of series-parallel connection in batteries to provide the necessary voltages and capacities.
The ER34614 MP current source is equipped with an electronic protection device designed to stop the discharge of an element into an external circuit when the discharge voltage drops below a safe value, without breaking the circuit.
During storage, transportation and operation it is strictly forbidden to conduct heating above 85°C, charge, short-circuit, expose to open flame, discharge in modes not provided for in the technical conditions, deform and open, allow direct contact with water.